VR2R-0265

回到這篇 SA Coverage

① SA Source

Context Before

Source: Nvidia VR NVL72 BoM and Power Budget Model ↗

Firstly, the connection between the GPU and the ConnectX NICs evolved from GB200 to GB300 then to Vera Rubin. For GB200, the GPU does not have direct access to the ConnectX-7. Instead, B200 connects to Grace CPU via C2C connection then the Grace CPU talks to the ConnectX-7 over PCIe 5. For GB300, Nvidia introduced NIC direct to ConnectX-8, which allows the B300 GPU to communicate directly with the ConnectX-8 NIC without going through the Grace CPU.

Evidence

Essentially, this means ConnectX-8 has two hosts, Grace CPU and B300 GPU. This improves latency in the backend network. However, for VR NVL72, the direct connection between Rubin GPU and ConnectX-9 is reverted back to the same design as GB200, as Rubin does not have PCIe bandwidth for two Connect-9. Rubin connects to Vera via C2C link, then Vera will connect to ConnectX-9 via PCIe6 lanes.

Context After

Secondly, the local NVMe storage for Rubin has been moved to a different location from that of NVMe storage in Grace Blackwell. Previously, local NVMe storage was managed by BlueField-3. For VR NVL72, the local NVMe storage is physically on the Orchid module managed by the ConnectX-9.

image

② Atomic Claim

Rubin 先透過 C2C link 連到 Vera,再由 Vera 透過 PCIe6 lanes 連到 ConnectX-9。

  • Epistemic Mode: ASSERTED
  • Mapping Status: PARTIAL

③ Semantic Frame

{
  "frame_type": "NARY_RELATION",
  "participants": [
    {
      "node": {
        "id": "04_knowledge_base/Vera Rubin",
        "label": "Rubin"
      },
      "role": "accelerator"
    },
    {
      "node": {
        "id": "04_knowledge_base/ConnectX-9",
        "label": "ConnectX-9"
      },
      "role": "network_device"
    },
    {
      "node": {
        "id": "04_knowledge_base/PCIe",
        "label": "PCIe6"
      },
      "role": "host_interface"
    }
  ],
  "qualifiers": {
    "condition_text": "Vera and C2C are plain text in this source claim; not independently canonicalized here",
    "numeric_mentions": [
      "6"
    ],
    "temporal_mentions": []
  },
  "relation_type": "RUBIN_TO_CONNECTX9_VIA_VERA"
}

④ Canonical Entity Mapping

RoleSurface LabelCanonical Target
acceleratorRubin04_knowledge_base/Vera Rubin
network_deviceConnectX-9ConnectX-9
host_interfacePCIe6PCIe

⑤ V2 Draft(需要修正時直接編輯)

Inline repair

只編輯以下三個 Draft 區塊。完成後將 review_action 設為 REQUEST_REPAIR,再手動執行 Repair Preview。
執行腳本前,Draft 不會寫入 Claim Store 或 Graph。

V2 Atomic Claim Draft

Rubin 先透過 C2C link 連到 Vera,再由 Vera 透過 PCIe6 lanes 連到 ConnectX-9。

V2 Semantic Frame Draft

{
  "frame_type": "NARY_RELATION",
  "participants": [
    {
      "node": {
        "id": "04_knowledge_base/Vera Rubin",
        "label": "Rubin"
      },
      "role": "accelerator"
    },
    {
      "node": {
        "id": "04_knowledge_base/ConnectX-9",
        "label": "ConnectX-9"
      },
      "role": "network_device"
    },
    {
      "node": {
        "id": "04_knowledge_base/PCIe",
        "label": "PCIe6"
      },
      "role": "host_interface"
    }
  ],
  "qualifiers": {
    "condition_text": "Vera and C2C are plain text in this source claim; not independently canonicalized here",
    "numeric_mentions": [
      "6"
    ],
    "temporal_mentions": []
  },
  "relation_type": "RUBIN_TO_CONNECTX9_VIA_VERA"
}

V2 Revision Metadata Draft

{
  "epistemic_mode": "ASSERTED",
  "mapping_status": "PARTIAL"
}

⑥ Human Review

請在 Properties 逐項確認:

  • 原文 → Atomic Claim 是否忠實
  • Atomic Claim → Semantic Frame 是否忠實
  • Canonical Entity mapping 是否正確
  • Epistemic mode 是否保留原文語氣
  • 最後選擇 review_action

Review state

Markdown 內文不是正式 approval。只有 Apply bridge 寫入的 Decision Ledger event 才是正式決策。