Each 28.8T NVLink Switch has 144 lanes of 200G (simultaneous bi-directional) which means each Switch has 24 lanes of 200G going to each connector.
Evidence
Copper flyover cables are used to connect each switch to the midplane, as the distances involved are too long for PCB traces.
Context After
This is also why the switches are further away from the midplane, to provide space for the routing of the flyover cables.
② Atomic Claim
使用 Copper flyover cable 將每顆 switch 連到 midplane,因為距離太長,不適合使用 PCB trace。
- Epistemic Mode:
ASSERTED - Mapping Status:
COMPLETE
③ Semantic Frame
{
"frame_type": "NARY_RELATION",
"participants": [
{
"node": {
"id": "04_knowledge_base/Copper",
"label": "Copper"
},
"role": "material"
},
{
"node": {
"id": "04_knowledge_base/Flyover cable",
"label": "flyover cable"
},
"role": "cable"
},
{
"node": {
"id": "04_knowledge_base/Midplane",
"label": "midplane"
},
"role": "destination"
},
{
"node": {
"id": "04_knowledge_base/PCB",
"label": "PCB"
},
"role": "unsuitable_medium"
}
],
"qualifiers": {
"condition_text": "距離過長,不適合 PCB traces",
"numeric_mentions": [],
"temporal_mentions": []
},
"relation_type": "SWITCH_TO_MIDPLANE_FLYOVER_CONNECTIVITY"
}④ Canonical Entity Mapping
| Role | Surface Label | Canonical Target |
|---|---|---|
| material | Copper | Copper |
| cable | flyover cable | 04_knowledge_base/Flyover cable |
| destination | midplane | Midplane |
| unsuitable_medium | PCB | PCB |